科学家利用VideometerLiq液体多光谱成像稳定分析系统发表牛奶蛋白浓度研究文章

  • 欧亚国际

    欢迎您来到欧亚国际科技官方网站!

    土壤仪器电话

    010-82794912

    品质至上,客户至上,您的满意就是我们的目标

    技术文章

    当前位置:  首页 > 技术文章

    科学家利用VideometerLiq液体多光谱成像稳定分析系统发表牛奶蛋白浓度研究文章

    发表时间:2021-04-16 15:15:08点击:1076

    来源:北京欧亚国际科技有限公司

    分享:

    blob.png

    blob.png

    科学系利用VideometerLiq液体多光谱成像系统,发表了题为A semi dynamic in vitro digestion study of milk protein concentrate dispersions structured with different polysaccharides的文章。VideometerLiq液体多光谱成像系统是新型液体成像系统。

    A semi dynamic in vitro digestion study of milk protein concentrate dispersions structured with different polysaccharides

    Abstract

    Hydrocolloids are often added as functional ingredients in foods, to better design the structure of the matrix and ensure food quality and optimal sensory properties. However, much less is known about their influence on the physical and chemical changes during gastric digestion. In this study, semi- continuous in vitro gastric digestion was applied on a model food system, prepared with milk protein concentrate (MPC) (3% w/v) and 1% alginate, pectin, guar gum, as well as a 1:1 mixture of alginate and pectin. The dynamics during simulated gastric digestion were observed by measuring particle size distributions, structuring at various length scales, as well as by evalsuating differences in protein  breakdown. Immediately after contact with the simulated gastric fluids, all samples showed extensive  aggregation and formation of different structures. MPC control dispersions (no polysaccharide) and  MPC containing alginate formed large inhomogeneous aggregates. The lack of structural  homogeneity affected the simulated gastric emptying: there were marked differences in the type of aggregates present at various times of emptying depending on the hydrocolloid present in the mixture. MPC containing pectin or guar gum formed macroscopically homogeneous dispersion, with rather  small protein aggregates showing a large population of particles between 60 and 100 µm of diameter,  with marked differences in microstructure. Pectin created large coacervates, while guar microscopic  phase separated systems. These dispersions showed a higher extent of protein digestion, due to the  larger surface area created for enzyme activity compared to the macroscopically phase separated  matrices. In all cases, there was a large undigested fraction at the end point of 140 min. SDS PAGE

    demonstrated differences in the casein peptides distribution depending on the type of polysaccharide  present during simulated gastric emptying. This in spite of similarities in cumulative protein emptied. It was concluded that in this semi-continuous in vitro gastric digestion model, structuring with polysaccharides has a significant impact on gastric emptying and protein digestion kinetics.

    Keywords

    Hydrocolloids, in vitro digestion, semi-dynamic, milk protein concentrate, food matrix

    • 土壤仪器品牌德国steps
    • 土壤仪器品牌奥地利PESSL
    • 土壤仪器品牌荷兰MACView
    • 土壤仪器品牌德国INNO_Concept
    • 土壤仪器品牌比利时WIWAM
    • 土壤仪器品牌德国GEFOMA
    • 土壤仪器品牌奥地利schaller
    • 土壤仪器品牌荷兰PhenoVation
    • 土壤仪器品牌法国Hi-phen系统
    • 土壤仪器品牌Videometer
    • 土壤仪器品牌比利时INDUCT(OCTINION)
    • 土壤仪器品牌美国EGC
    • 土壤仪器品牌HAIP
    • 土壤仪器品牌植物遗传资源学报
    欧亚国际